Production Scale ETO Sterilizer

Description

Production Scale ETO Sterilizer or industrial eo gas sterilizer has been specially designed for sterilization of products sensitive to high temperature and to humidity (Syringes, DE fluxers, Catheters, Cartridges for Dialysis, Plastic articles, Bandages, Sutures etc.).  Sterilizer can be uses even for sterilization of powders which deteriorate by heating exposure. For the wide range of product that can be treated, such sterilizer find application in Disposable Surgical Products, Para Pharmaceutical and Pharmaceutical Industry, Laboratories, Hospital and Food Processing Industries.

Adinath Ethylene Oxide Gas Sterilizer Manufacturer can be realized in to satisfy different requirements working under pressure (1.5 kg/cm² + vacuum) with mixtures of Ethylene Oxide and Carbon Oxide (usual composition 10% ETO + 90% CO₂, 20% ETO + 80% CO₂) Ethylene Oxide gas infiltrates packages as well as products themselves to kill microorganisms that are left during production or packaging processes. This gas, mixed with air at a ratio of at least 3% ETO gas, forms an explosive mixture. Pure ETO gas boiling point is 10.73 ºC at atmospheric pressure. Most of the time, it is mixed with Nitrogen or CO2. EO Gas Sterilizers uses to sterilize to surgical instruments and medical disposables.

 

The system has been designed to operate on eto+co2 combination gas cylinders. The chamber and all contact parts shall be made from S.S 304. The chamber has been provided with a single door, easy locking arrangement and silicon gasket for leak proof operation. Electronically controlled heating system to ensure uniform heating of the chamber at 50 degrees centigrade. The chamber is provided with a adequate capacity rotary vacuum pump enclosed in sturdy cabinet duly powder coated for durability. We provide four of control switches with built in indicator light to regulate evacuation, feeding of gas, fresh air inlet through filter and aeration facility. Ethylene Oxide Gas Sterilization Unit is compact stand-alone sterilizer chamber.

Salient Features of Production Scale ETO Sterilizer

Working Principle of Production Scale ETO Sterilizer

Ethylene Oxide (EO) sterilization stands out as a highly effective sterilization method, offering several distinct advantages over conventional steam sterilizers. As a dry and cold sterilization process—operating at a low temperature of approximately 50ºC—EO sterilization is exceptionally well-suited for sterilizing sensitive and expensive medical equipment that cannot withstand high heat or moisture.

 

One of the key benefits of Ethylene Oxide sterilization is its superior penetration capability, allowing it to effectively sterilize complex and delicate medical devices. This makes it the preferred choice for sterilizing items such as cardiac catheters, stents, intraocular lenses (IOLs), medical tubing, various endoscopic scopes, and sharp surgical instruments.

 

Beyond its penetration efficiency, EO sterilization’s gentle mode of action helps preserve the structural integrity of surgical accessories and disposable items. This unique property significantly extends the usable life of medical instruments, enabling safe reprocessing and repeated use—making it a cost-effective and sustainable sterilization solution for hospitals and healthcare facilities.

 

For medical device manufacturers and healthcare providers seeking a reliable, low-temperature sterilization method that ensures both safety and equipment longevity, Ethylene Oxide sterilization remains an industry-preferred solution.

 

Working Principle of Production Scale ETO Sterilizer

Standard Operating Values of Production Scale ETO Sterilizer

Sterilization Time

Usual gas exposure time is 3 to 40 hours. Sterilization time depends upon type of packaging and other process parameters.

 

Product Temperature

35˚C to 60˚C set temperature value is non- stop holed by force circulation of water inside the jacket and optionally inside this system is very reliable with no risk of overheating and temperature differences by steam use.

 

Product Humidity

40 to 70 RH value is obtained with sterilizer under vacuum condition to allow best conditioning of sterilization load.

 

Gas Concentration inside the Sterilizer

Variable on the basis of used gas mixture and operating pressure.

 

Application

  • Disposable Surgical Products
  • Para Pharmaceuticals
  • Pharmaceutical Industry
  • Spices
  • Food Industry

 

Chamber Size

20 Cubic Feet to 30 Cubic Meters models available as per requirements.

Advantages of Production Scale ETO Sterilizer

Key Features of Production Scale ETO Sterilizer

  • Large Chamber Capacity
    Designed with high-volume chambers to accommodate bulk sterilization of medical devices and pharmaceutical products. Enables efficient large-scale production sterilization in a single cycle.

 

  • PLC-Based Automated Control System
    Provides precise regulation of gas concentration, temperature, humidity, and exposure time. Supports programmable cycles for consistent, validated, and repeatable sterilization results.

 

  • Low-Temperature Sterilization Process
    Operates at controlled low temperatures, making it suitable for heat and moisture-sensitive materials. Ensures effective sterilization without compromising product integrity.

 

  • Advanced Gas Safety and Leak Detection System
    Equipped with gas concentration monitoring and leak detection for enhanced operator safety. Minimizes ethylene oxide exposure risks during and after sterilization cycles.

 

  • Robust Industrial-Grade Construction
    Built with high-grade stainless steel chambers for durability and corrosion resistance. Ensures compliance with GMP standards and long-term operational reliability in production environments.

FAQ for Production Scale ETO Sterilizer

The system operates with ETO + CO₂ combination gas cylinders in mixtures of 10% ETO + 90% CO₂, 20% ETO + 80% CO₂, or 30% ETO + 70% CO₂. It works under pressure (up to 1.5 kg/cm² + vacuum) at controlled temperatures of 35°C to 60°C (typically around 50°C) with humidity maintained at 40–70% RH under vacuum for optimal conditioning.

Chamber volumes range from 20 cubic feet to 30 cubic meters and can be customized to specific product requirements. Both semi-automatic and fully automatic (PLC-based) models are offered. Single-door and double-door configurations are available, with chambers constructed from SS 304 and fitted with silicon gaskets for leak-proof operation.

Ethylene oxide gas penetrates packaging and products at low temperature (~50°C) to kill microorganisms without the high heat or moisture of steam sterilization. This makes it ideal for complex or delicate devices such as cardiac catheters, stents, intraocular lenses, medical tubing, and endoscopic instruments. Usual gas exposure time ranges from 3 to 40 hours depending on packaging and process parameters.

The unit features electronically controlled heating for uniform temperature, a rotary vacuum pump, pneumatically operated automatic cartridge puncturing, and an advanced gas safety and leak-detection system. Construction uses high-grade stainless steel for durability and corrosion resistance, ensuring GMP compliance and long-term reliability in production environments.

It efficiently handles large volumes of medical devices and pharmaceutical products in a single cycle, sterilizes heat- and moisture-sensitive materials without damage, provides deep penetration into complex geometries and sealed packages, and delivers consistent, validated results via automated PLC control. It complies with international standards such as ISO 11135 and GMP while minimizing product damage and production downtime.

Yes — Adinath International Production Scale ETO Sterilizer complies to cGMP, MHRA, FDA and WHO-GMP standards, with optional CE marked equipments and 21 CFR Part 11 software compliance for the HMI/PLC. Machine contact parts having Stainless Steel 316L grade materials with validation documents having IQ, OQ, DQ validation protocols as optional. Organization is ISO 9001:2015 certified.

Manufacturing lead time is generally 7 to 14 weeks from order confirmation. Further it takes 2 to 8 weeks for international shipping depending upon destination. Order can be expediate sooner or later as per specific buying requirements. Destination specific certifications like US FDA, EU, ANVISA, SFDA. CE can add 3 to 6 weeks additionally.

Yes, Adinath International Production Scale ETO Sterilizer export this machine to more than 48 countries of this world including America, Europe, Asia, Middle East, Africa, CIS and Australia sub continents. Please visit our clientele page for complete list of our customers worldwide. See the turnkey project page for our complete plant offerings.

Service of skilled engineers and technicians provided for technical support of supplied equipments. Installations, commissioning, training and IQ, OQ, DQ validations performed by qualified engineers. Remote support through video call, phone, email and other modes provided for international installations. Spare parts of Production Scale ETO Sterilizer stocked at our premises in Ahmedabad and shipped immediately after ordering. Standard 12 months manufacturing warranty included with supplied equipment.

Talk to Our Engineers

Partner with Industry Experts

Connect with our engineering team to discuss your specific production requirements. We provide customized, cGMP-compliant machinery solutions designed to optimize your manufacturing facility and maximize output.

Established in 1998, Adinath International is a leading pharmaceutical machinery manufacturer in India. We deliver cGMP and FDA-compliant processing, filling, and packaging solutions globally. From liquid filling to tablet presses, our sturdy, cost-effective, and hygienic machines serve the pharma, biotech, food, and cosmetic industries worldwide.

Contact Info

©2012-2026 Adinath International | Theme Developed By Pharma Machinery Manufacturer | Website updated on: 21 November 2026