Steam Sterilizer

Description

Steam Sterilizer or autoclave Steam sterilization is a wet-heat process, and the low water content of oils result in sterilization being effectively based on dry heat rather than wet, requiring significantly higher holding times. Sterilizer uses saturated steam at 121–132 °C. Steam sterilization has many advantages. It is a simple, rapid, effective, safe, environment-friendly and low-cost sterilization method.

Our vertical autoclaves are designed to comply with all relevant industry guidelines and standards, including NABH standards, ensuring safety, reliability, and regulatory compliance. On request, we also offer complete IQ/OQ/PQ calibration documentation (Installation Qualification, Operational Qualification, and Performance Qualification) at an additional cost, helping you maintain quality assurance and audit readiness.

 

Built with flexibility in mind, our vertical autoclaves are highly customizable, allowing you to tailor features and specifications to match your specific budget and operational requirements. We also offer a wide range of optional accessories to enhance functionality, including a temperature chart recorder, digital temperature indicator, and PID controller for precise process control. Additionally, our autoclaves come with the provision to attach a dot matrix printer for convenient record-keeping and documentation.

 

Whether you need a standard configuration or a fully customized solution, our vertical autoclaves deliver dependable performance backed by industry-standard compliance and support.

Salient Features of Steam Sterilizer

Working Principle of Steam Sterilizer

  • Set the autoclave and materials to be sterilized on a table or shelf.
  • Prepare the load that needs to be sterilized.
  • Turn the autoclave lid counterclockwise and remove it.
  • Pour about 1 liter of water into the bottom chamber.
  • Position the filled basket or dressing drum inside the autoclave.
  • Inspect the rubber gasket to confirm it’s properly placed and undamaged.
  • Set the lid on top, press down, and rotate it clockwise until fully secured.
  • When closed correctly, both handles should sit parallel to each other, one above the other on each side.
  • Steam will begin forming after a few minutes, and once pressure reaches 15±2 lb psi, steam will forcefully release through the stopcock.
  • Allow sterilization to continue for 15 minutes, then switch off the power and use forceps or a cloth to lift out the stopcock whistle/valve from the vent tube.
  • The remaining steam will release completely, but caution is needed as it will be hot.
  • Confirm no steam remains inside and that the pressure gauge reads zero.
  • Twist the lid counterclockwise to open it and lift it away from the base.
  • Take out the rack or dressing drum and store it somewhere safe.
  • Drain any remaining water from the base chamber, then close the autoclave by placing the lid back on and turning it clockwise.
  • Reinsert the stopcock whistle/valve into the vent tube, ready for the next sterilization cycle.
Working Principle of Steam Sterilizer

Technical Specification of Steam Sterilizer

Construction Standard Model Double Walled Model Triple Walled Model
MOC Exterior MS Painted SS 304 (mirror finish) SS 304 (mirror finish)
No. of walls Double Double Triple
Lid Polished MS SS 304 SS 304
Interior SS 304 with silicon gasket
Working Pressure 15 to 20 PSI
Working Temperature 121°C to 125°C
Controller 15 PSI & 121°C
Pressure display Analog dial gauge.
Timer Mechanical timer
Hydraulic tested Hydraulically Tested up to 40 psi.
Basket Stainless steel basket Stainless steel basket Not Required
Power supply 220 Volts, Single Phase, 50Hz
Standard Fittings
  • Low water indicator
  • Automatic pressure switch
  • Pedal lifting device
  • Steam release valve
  • Water outlet valve
  • Spring loaded safety valve.
  • Power cable with three pin tops
Optional Accessories
  • Fully stainless-steel construction (GMP)
  • Up to 134°C temperature range
  • PID temperature controller cum timer with alarm (buzzer)
  • PLC with HMI interface with data logging
  • 21 CFR Part 11 software
  • Thermal Printer
  • Lower water cut-off

Advantages of Steam Sterilizer

Key Features of Steam Sterilizer

  • Saturated Steam Sterilization
    Utilizes high-temperature saturated steam to effectively destroy microorganisms and spores. Ensures reliable and complete sterilization of materials in every cycle.

 

  • Microprocessor-Based Control System
    Advanced digital controls allow precise regulation of temperature, pressure, and cycle time. Enables automatic operation with programmable sterilization cycles for consistency.

 

  • Safety Door Locking Mechanism
    Ensures the door remains securely locked during high-pressure and high-temperature cycles. Prevents accidental opening, protecting operators from steam-related hazards.

 

  • Vacuum-Assisted Air Removal
    Pre-vacuum system eliminates trapped air for better steam penetration and sterilization efficiency. Post-cycle vacuum aids in quick drying of sterilized items.

 

  • Robust Stainless Steel Construction
    Chamber and jacket made of SS316/SS304 for high durability and corrosion resistance. Ensures compliance with GMP standards and long-term operational reliability.

 

Steam Sterilization principle is centered around exposing items to steam contact for a specified amount of time and under specified temperature conditions. Steam sterilization is typically used in hospitals for sterilizing the surfaces of wrapped goods or hollow items, and contains three important parameters: Temperature, steam under pressure and time.

The process is conducted by supplying dry, saturated steam under pressure into an autoclave. The heat from the condensation of steam envelops the items in the sterilizer and kills the microorganisms in an easy and fast manner. It does so by irreversibly damaging the cells by coagulation.

 

FAQ for Steam Sterilizer

Models are available in standard, double-walled, and triple-walled configurations. Exteriors range from MS painted (standard) to SS 304 mirror finish (higher models). Interiors are SS 304 with silicone rubber gaskets. Working pressure is typically 15–20 PSI and temperature 121–125 °C (optional up to 134 °C). Chambers are hydraulically tested up to 40 psi, and baskets are stainless steel (not required on triple-walled models).

Water is added to the base chamber, the load is placed in the stainless-steel basket, and the lid is secured. Steam is generated until pressure reaches approximately 15 ± 2 lb psi. The cycle runs for about 15 minutes at the set temperature/pressure. Power is then switched off, residual steam is safely released via the stopcock, pressure is confirmed at zero, and the sterilized load is removed. A foot pedal aids lid opening, and gauges/indicators monitor pressure and water level.

Standard features include digital temperature display and controller, automatic pressure regulation switch, water-level indicator, spring-loaded safety valve, steam release and water inlet/outlet valves, and a pedal lifting device. Optional upgrades include PID temperature controller with timer and alarm, low-water cut-off, vacuum-assisted air removal (pre- and post-vacuum), safety door locking, PLC with HMI, data logging, thermal printer, and 21 CFR Part 11 software.

They are widely used in pharmaceutical, biotech, nutraceutical, herbal & Ayurvedic, cosmetic, and chemical industries, as well as hospitals, labs, and food & beverage settings. Ideal materials include glassware, surgical instruments, liquids, textiles, laboratory cultures, and other heat-stable items requiring complete elimination of microorganisms while meeting GMP and sterility-assurance standards.

The sterilizers are designed to meet relevant industry guidelines including NABH standards. Optional IQ/OQ/PQ (and DQ) validation documentation is available. Contact parts can be SS 316L for higher compliance needs. Machines support cGMP, MHRA, FDA, and WHO-GMP requirements (with optional CE marking and 21 CFR Part 11 software). Power voltage can be customized, full stainless-steel GMP construction is offered, and after-sales support includes installation, training, remote assistance, and spare parts with a standard 12-month warranty.

Yes — Adinath International Steam Sterilizer complies to cGMP, MHRA, FDA and WHO-GMP standards, with optional CE marked equipments and 21 CFR Part 11 software compliance for the HMI/PLC. Machine contact parts having Stainless Steel 316L grade materials with validation documents having IQ, OQ, DQ validation protocols as optional. Organization is ISO 9001:2015 certified.

Manufacturing lead time is generally 7 to 14 weeks from order confirmation. Further it takes 2 to 8 weeks for international shipping depending upon destination. Order can be expediate sooner or later as per specific buying requirements. Destination specific certifications like US FDA, EU, ANVISA, SFDA. CE can add 3 to 6 weeks additionally.

Yes, Adinath International Steam Sterilizer export this machine to more than 48 countries of this world including America, Europe, Asia, Middle East, Africa, CIS and Australia sub continents. Please visit our clientele page for complete list of our customers worldwide. See the turnkey project page for our complete plant offerings.

Service of skilled engineers and technicians provided for technical support of supplied equipments. Installations, commissioning, training and IQ, OQ, DQ validations performed by qualified engineers. Remote support through video call, phone, email and other modes provided for international installations. Spare parts of Steam Sterilizer stocked at our premises in Ahmedabad and shipped immediately after ordering. Standard 12 months manufacturing warranty included with supplied equipment.

Talk to Our Engineers

Partner with Industry Experts

Connect with our engineering team to discuss your specific production requirements. We provide customized, cGMP-compliant machinery solutions designed to optimize your manufacturing facility and maximize output.

Established in 1998, Adinath International is a leading pharmaceutical machinery manufacturer in India. We deliver cGMP and FDA-compliant processing, filling, and packaging solutions globally. From liquid filling to tablet presses, our sturdy, cost-effective, and hygienic machines serve the pharma, biotech, food, and cosmetic industries worldwide.

Contact Info

©2012-2026 Adinath International | Theme Developed By Pharma Machinery Manufacturer | Website updated on: 21 November 2026