Cath Lab ETO Sterilizer

Description

Cath Lab ETO Sterilizer or hospital Eto sterilizer mainly uses to sterilize medical and pharmaceutical products that cannot support conventional high temperature steam sterilization – such as devices that incorporate electronic components, plastic packaging or plastic containers.

Ethylene Oxide gas infiltrates packages as well as products themselves to kill microorganisms that are left during production or packaging processes. This gas, mixed with air at a ratio of at least 3% ETO gas, forms an explosive mixture. Pure ETO gas boiling point is 10.73 ºC at atmospheric pressure. Most of the time, it is mixed with Nitrogen or CO2. EO Gas Sterilizers uses to sterilize ot surgical instruments and medical disposables.

 

The system has been designed to operate on single use disposable type, EO 100% gas cartridges of 40 / 100 / 170 grams. The chamber and all contact parts shall be made from S.S 304. The chamber has been provided with a single door, easy locking arrangement and silicon gasket for leak proof operation. Electronically controlled heating system to ensure uniform heating of the chamber at 50 degrees centigrade. The chamber is provided with a adequate capacity rotary vacuum pump enclosed in sturdy cabinet duly powder coated for durability. We provide four of control switches with built in indicator light to regulate evacuation, feeding of gas, fresh air inlet through filter and aeration facility. Ethylene Oxide Gas Sterilization Unit is compact stand-alone sterilizer chamber.

Salient Features of Cath Lab ETO Sterilizer

Working Principle of Cath Lab ETO Sterilizer

Ethylene Oxide (EO) sterilization stands out as one of the most reliable and versatile sterilization methods available today, offering several key advantages over traditional steam sterilization. As a dry, low-temperature process operating at around 50°C, EO sterilization is exceptionally well-suited for sterilizing heat-sensitive and expensive medical devices that cannot withstand the high temperatures and moisture involved in steam-based sterilization.

 

One of the standout benefits of Ethylene Oxide sterilization is its remarkable penetration capability, allowing it to effectively sterilize items with complex geometries, narrow lumens, and delicate components. This makes it the preferred choice for sterilizing high-value medical instruments such as cardiac catheters, stents, intraocular lenses (IOLs), various tubing systems, endoscopes and other specialized scopes, as well as sharp surgical instruments.

 

Beyond its superior sterilization efficacy, EO sterilization also helps extend the functional lifespan of surgical accessories and disposable items. Because the process is gentle on materials, it minimizes wear and degradation, enabling many instruments and disposables to be safely reused multiple times. This not only improves cost-efficiency for healthcare facilities but also supports sustainable medical practices.

 

Overall, Ethylene Oxide sterilization combines safety, precision, and material compatibility—making it an essential technology for hospitals, medical device manufacturers, and sterilization service providers seeking dependable, low-temperature sterilization solutions.

Working Principle of Cath Lab ETO Sterilizer

Technical Specification of Cath Lab ETO Sterilizer

Model AETOS – 2.6 AETOS – 4.5 AETOS – 8
Working Capacity in Cu. Ft. 2.6 4.5 8
Working Volume 70 Liters 125 Liters 200 Liters
Chamber Size 12” (W) x 12” (H) x 32”   12” (W) x 12” (H) x 54” (D) OR 15” (W) x 15” (H) x 36” (D) 20” (W) x 18” (H) x 38” (D) OR 16” (W) x 16” (H) x 54” (D)
Sterilant Gas 40 grams cartridge 100 grams cartridge 170 grams cartridge
Sterilization Cycle Warm & Cold Cycles are possible. Warm & Cold Cycles are possible. Warm & Cold Cycles are possible.
Aeration In-built aeration facility provided. In-built aeration facility provided. In-built aeration facility provided.
Utility Compressed Air (100 psig) Compressed Air (100 psig) Compressed Air (100 psig)
Power Supply 1 K.W. 2 K.W. 2.5 K.W.
Power Voltage 220 volts, Single Phase, 50 Hertz 220 volts, Single Phase, 50 Hertz 220 volts, Single Phase, 50 Hertz

Advantages of Cath Lab ETO Sterilizer

Key Features of Cath Lab ETO Sterilizer

  • Low-Temperature Ethylene Oxide Sterilization
    Operates at low temperatures, making it ideal for heat and moisture-sensitive cath lab devices. Ensures effective sterilization without damaging delicate instruments or components.

 

  • Microprocessor/PLC-Based Control System
    Provides precise control over gas concentration, temperature, humidity, and exposure time. Enables programmable cycles for accurate and repeatable sterilization performance.

 

  • Deep Penetration Capability
    Effectively penetrates narrow lumens, tubing, and complex device geometries used in cath labs. Ensures thorough sterilization of intricate catheter and cardiac device designs.

 

  • Safety Gas Handling System
    Equipped with leak detection and gas evacuation systems to ensure operator safety. Minimizes exposure risk to ethylene oxide gas during and after sterilization cycles.

 

  • Compact and Space-Efficient Design
    Designed to fit within cath labs and hospital sterile processing areas. Ensures efficient workflow integration without requiring large installation space.

FAQ for Cath Lab ETO Sterilizer

Ethylene oxide gas infiltrates packages and products to kill microorganisms remaining from production or packaging. The process is a dry, low-temperature method (around 50°C) that operates under vacuum. The system uses single-use 100% EO gas cartridges, electronically controlled heating for uniform chamber temperature, a rotary vacuum pump, and controls for evacuation, gas feeding, filtered fresh-air inlet, and aeration—all within a compact stainless-steel (SS 304) chamber.

The entire sterilization cycle runs under negative pressure (vacuum), minimizing the chance of gas leakage or operator exposure compared with cylinder-based systems. It includes continuous post-cycle purging/aeration until the door is opened, leak-proof silicon gasket sealing, easy door locking, and a safety gas handling system with evacuation features. Single-use EO cartridges with fixed concentrations further prevent over- or under-exposure.

Three models are offered:

  • AETOS-2.6: 2.6 cu. ft. / 70 liters working volume, 40 g EO cartridge
  • AETOS-4.5: 4.5 cu. ft. / 125 liters, 100 g cartridge
  • AETOS-8: 8 cu. ft. / 200 liters, 170 g cartridge

All support warm and cold cycles, include built-in aeration, require compressed air (100 psig), and run on 220 V single-phase power (adjustable to local requirements). Chamber dimensions vary by model for flexibility in cath-lab or hospital settings.

EO sterilization operates at low temperature (~50°C) and is gentle on heat- and moisture-sensitive materials, preventing damage to delicate cardiac devices, plastics, and electronics. It provides excellent penetration into complex geometries, narrow lumens, and tubing—ensuring thorough sterilization of catheters, stents, and similar items—while also helping extend the usable life of instruments and disposables. It complies with international standards such as ISO 11135.

Yes, the unit features built-in aeration so sterilization and aeration occur continuously in the same chamber, eliminating the need to transfer loads and reducing gas-exposure risk. It uses convenient, single-use pure EO 100% gas cartridges (40 g / 100 g / 170 g matching chamber size). These eliminate cylinder deposits, transportation issues, and concentration errors, ensuring precise gas dosing for sterility without residual overexposure.

Yes — Adinath International Cath Lab ETO Sterilizer complies to cGMP, MHRA, FDA and WHO-GMP standards, with optional CE marked equipments and 21 CFR Part 11 software compliance for the HMI/PLC. Machine contact parts having Stainless Steel 316L grade materials with validation documents having IQ, OQ, DQ validation protocols as optional. Organization is ISO 9001:2015 certified.

Manufacturing lead time is generally 7 to 14 weeks from order confirmation. Further it takes 2 to 8 weeks for international shipping depending upon destination. Order can be expediate sooner or later as per specific buying requirements. Destination specific certifications like US FDA, EU, ANVISA, SFDA. CE can add 3 to 6 weeks additionally.

Yes, Adinath International Cath Lab ETO Sterilizer export this machine to more than 48 countries of this world including America, Europe, Asia, Middle East, Africa, CIS and Australia sub continents. Please visit our clientele page for complete list of our customers worldwide. See the turnkey project page for our complete plant offerings.

Service of skilled engineers and technicians provided for technical support of supplied equipments. Installations, commissioning, training and IQ, OQ, DQ validations performed by qualified engineers. Remote support through video call, phone, email and other modes provided for international installations. Spare parts of Cath Lab ETO Sterilizer stocked at our premises in Ahmedabad and shipped immediately after ordering. Standard 12 months manufacturing warranty included with supplied equipment.

Talk to Our Engineers

Partner with Industry Experts

Connect with our engineering team to discuss your specific production requirements. We provide customized, cGMP-compliant machinery solutions designed to optimize your manufacturing facility and maximize output.

Established in 1998, Adinath International is a leading pharmaceutical machinery manufacturer in India. We deliver cGMP and FDA-compliant processing, filling, and packaging solutions globally. From liquid filling to tablet presses, our sturdy, cost-effective, and hygienic machines serve the pharma, biotech, food, and cosmetic industries worldwide.

Contact Info

©2012-2026 Adinath International | Theme Developed By Pharma Machinery Manufacturer | Website updated on: 21 November 2026